Product Code : EDS-LE-12317
Eduscope India is a leading Sterility Test Apparatus Manufacturer,and suppliers in India, Sterility Test Apparatus Manufacturer,and suppliers in South Africa, Sterility Test Apparatus Algeria (Algiers), Sterility Test Apparatus Angola (Luanda), Sterility Test Apparatus Argentina (Buenos Aires), Sterility Test Apparatus Armenia (Yerevan), Sterility Test Apparatus Australia (Canberra), Sterility Test Apparatus Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.).

Description

Sterility Test Apparatus 

The sterility tests in this system is done by the Bacteria-Retentive membranes filter method.

This Apparatus is made in total 316 Stainless Steel.

This apparatus is used for filtering liquid samples. 

A 47 mm membrane filter is installed in a suitable holder. 

The liquid sample is drawn through this sterile membrane filter to concentrate any contaminating micro-organisms on the filter surface. 

After filtration is completed, sterile flushing fluid is passed into the funnels, rinsing all sample residues through the filters so that it cannot possibly inhibit growth of the retained micro-organisms. 

After this, the filter is sectioned and transferred to media for culturing. 

If growth is not visible after the incubations period, the sample passes the test.


















   